Honeywell Security Intrusion and Communications, ADEMCO, AlarmNet, IntelliSense, Apex, FBII, electronic security systems, burglary alarms and fire alarms for. Installation manual for the Honeywell wireless three-zone sensor. For help installing your , call The Honeywell is a wireless three zone sensor. Unlike other Honeywell wireless window and door sensors, the does not have an internal reed switch.

Author: Migul Samuzilkree
Country: Iraq
Language: English (Spanish)
Genre: Literature
Published (Last): 27 July 2009
Pages: 493
PDF File Size: 4.91 Mb
ePub File Size: 3.92 Mb
ISBN: 313-6-96325-733-6
Downloads: 61946
Price: Free* [*Free Regsitration Required]
Uploader: Male

The Multi-Point Universal Transmitter may have three contact loops connected to it. Surface wiring should enter via the thin “breakout” area provided in. The unit may, however, be installed in any direction, as long as the relationship of the unit to its mounting plate is maintained.

Attach the case back to the mounting plate by sliding the keyhole slots in the case back down. Replace battery only with: The open slot at the other end of the unit cannot be used as a cover pry-off. Do not recharge, disassemble, heat above. Although two holes are provided in the unit that would permit mounting directly to a surface holes “A” in Diagram 2it is recommended that the mounting plate be ademck, as described below, for ease in removing the daemco for servicing should it become necessary.

No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized.

Honeywell ADEMCO 5817 3 Point Wireless Transmiter

This warranty replaces any previous warranties and is the only warranty made by Seller on this product s. Disengage the supplied mounting plate from the unit by inserting the blade of a small screwdriver into the locking tab release window see Diagram 2 and pressing it against the case locking tab see Diagram 1 while sliding the plate downward along the case back.

Risk of fire, explosion, and burns. Page of 2 Go. Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fireor other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result.

  COMO ORAR R.A.TORREY PDF

It is not necessary to program the transmitter IDs during installation. Don’t show me this message again. The installer should assume the responsibility of developing and offering a regular maintenance. The locking tab will click as the case back locks in place.

Regular maintenance and inspection at least annually by the installer and frequent testing by. Seller shall have no obligation under this Limited Warranty or otherwise if the product s is altered or improperly repaired or serviced by anyone other than Honeywell factory service.

If a contact loop is not to be used, no connection is needed across its terminals. For this application, the alignment guide strip along one edge of the plate serves no function and may be broken away, if desired. For UL installations, no contact in any of the loops may be more than 3 feet from the transmitter. Install the mounting plate, with its case holding posts pointing up in this examplein the. The should be treated as “RF” i. Dispose of used batteries promptly. Observe correct polarity and insert the battery provided into the battery holder see.

Comments to this Manuals Your Name. The description that follows assumes that the unit will be mounted as shown in the diagrams. By pressing ‘print’ button you will print only current page.

Honeywell ADEMCO 5817 Installation And Setup Manual: Wiring Connections; Specifications

Got it, continue to print. With the battery still not inserted, connect the loop wiring to the unit’s terminals see Diagram 2.

Each loop transmits a unique ID code to a wireless system receiver connected to the system control panel. For UL installations with fire zones, the position 4 ON setting must not be used.

  BRAHMA SUTRA BHASHYA TELUGU PDF

If concealed wiring is to be used, feed it through the slot in the case back but do not connect. Mounting For proper orientation of the unit in relation to its wall mounting plate and the loop wiring, read all of this section before installing the unit. If concealed wiring is to be used, feed the wires through the concealed wiring entry hole at. Complain wrong Brand wrong Model non readable. Remove the transmitter’s cover if not already off as described in Mounting Step 1.

A built-in cover tamper switch is activated when the cover is removed. Add to my manuals Add. The Primary Loop has several DIP switch selectable options that determine its connection requirements, response, and transmission characteristics see DIP switch setting table on next page.

Wiring Connections; Specifications – Honeywell ADEMCO Installation And Setup Manual [Page 2]

Seller’s obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product s which is proved not in compliance with Seller’s specifications or proves defective in materials or workmanship under normal use and service. Except in the case of the position 4 ON setting, the Auxiliary loops are not affected by. Recommendations must be included for a specific. Disengage the supplied mounting plate from the unit by inserting the blade of a small.

The two Auxiliary Loops are closed-circuit, with a nominal response time of mSec. Enter text from picture: When a satisfactory location is found, remove the battery and proceed with installation. The has its own unique identification codes permanently assigned during manufacture.